CCAI-70-WEB-cl
image image image image image image

SAVE THE DATE

CCAI October 21-24

Fire Investigation Training Seminar

 

Watch the video


CLICK HERE

From Out of the Abyss...

This week’s article from the past is titled Incendiary Fires Can Be Spotted and was written by Benjamin Horton, CPCU, who was President of the National Adjuster Traing School in Louisville, Kentucky..  It is taken from the Decembe 1968 Vol. XVI No.5 issue.

Incendiary Fires Can Be Spotted 

In the new issue of NFPA Journal®, President Jim Shannon said the Association will focus on the leading causes of home fires, including cooking. "We also need to continue to push hard for home fire sprinklers. That's still a large priority for NFPA, and we plan to work very aggressively in 2014 on our residential sprinkler initiative," he said.

Read more...

From the Danish Journal of Archaeology

Abstract

During excavations of the Viking-age ring fortress Borgring, Denmark, traces of a devastating fire was uncovered. The National Forensic Services of the Danish Police were invited to participate in a novel collaboration, applying contemporary forensic fire investigation to an archaeological site. This paper presents the results and sets a benchmark for future applications. The investigation leads to a revised reconstruction of the fortress and the development of the fire. The application of fire investigation methods, following the Daubert standard criteria, enhance the documentation and analysis of archaeological sites, while archaeological methods show significant potential at modern fire scenes.

Read more...

BY VYTO BABRAUSKAS

SHOCK, INJURY, OR DEATH {ELECTROCUTION) from the passage of electric current through a human body has been studied for more than a century. The level of response or injury depends on the magnitude of the current and also on the frequency, whether it is direct current (DC), power line alternating current (AC), or AC voltages of higher frequency. Some typical values are shown in Table 1.1 Children are generally more sensitive than adults; thus, guidelines often assume that a child is the person to be protected. With firefighting, however, this assumption is not reasonable. Furthermore, protection against a startle reaction is the most severe level of protection. A startle reaction is described as one in which a person jumps because of a small shock that does not injure the person. No direct electrical injury occurs because of startling; there is some hazard caused by jumping, but it is remote.

The "inability to let go" of an energized conductor that has been accidentally grabbed can cause pain and injury if the current increases to an injurious level. This is also called "muscle tetanization." Thus. Many safety requirements are based on a safety-factor-reduced value of the let-go current, even though this is quite a conservative stance. Matters are further complicated. Since individuals show variation in their responses and standards, bodies typically pick a very conservative level (often the 0.5 percentile) instead of the 50-percentile value. Physiological effects of electric current, furthermore, depend strongly on frequency. The most dangerous frequencies are the 50- or 60-Herz (Hz) power line frequencies. The human body becomes less sensitive to electric current at high frequencies.2 Dalziel3 has published a useful summary of safety guidance on electric shock.

Read more...

NHTSA - Shower Door may Increase Fire Risk/FMVSS 302 (Jayco, Inc.)A

Report Receipt Date: AUG 01, 2016 
NHTSA Campaign Number: 16V568000 
Component(s): EQUIPMENT 
Potential Number of Units Affected: 2,240

Manufacturer: Jayco, Inc.

SUMMARY:

Jayco, Inc. (Jayco) is recalling certain model year 2013-2017 Redhawk motorhomes manufactured August 1, 2012, to June 24, 2016. The affected vehicles are equipped with shower curtains that may not adequately resist catching fire in the presence of an ignition source. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 302, "Flammability of Interior Materials."

CONSEQUENCE:

A flammable shower curtain may further fuel a fire, increasing the risk of injury.

REMEDY:

Jayco has notified owners, and dealers will replace the shower curtains with curtains made with fire retardant, free of charge. The recall began August 11, 2016. Owners may contact Jayco customer service at 1-800-283-8267. Jayco's number for this recall is 9903318.

NOTES:

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.

Banner

Location

1279 North White Avenue
Pomona, California 91768
Phone:  (909) 865-5004
Fax (909) 865-5024
8:00 am - 5:00 pm
Monday - Friday

Disclaimer

This is the official website of the California Conference of Arson Investigators.

The information published on this website... more...